Scope of Practice Comparison
by Michael O'Handley
Introduction
This is a side-by-side comparison of the Standards of Practice (S.O.P.) of the
four national home inspector associations – ASHI , NAHI, AII, and NACHI, as well
as the SOP that the Washington Home Inspectors Legislative Advisory Group (WHILAG)
is proposing for the state of Washington.
In
order to understand this comparison, the reader must understand that this
document is essentially a translation of all of these SOP’s. All association
paragraph numbering has been discarded. In order to differentiate one entity’s
position from the next, the text is color-coded – black text for ASHI, blue text
for NAHI, green text for AII, brown text for NACHI, and purple text for WHILAG.
Comments are
also grouped by action verbs. Where more than one association uses the same
verb, those comments are grouped together. When there are no common action verbs
there are breaks in the texts.
Below are
links to the actual SOP’s:
A.S.H.I. Standards of
Practice:
http://www.ashi.org/inspectors/standards/standards.asp
N.A.H.I. Standards of
Practice:
http://www.nahi.org/public/department214.cfm
A.I.I. Standards of Practice
http://www.inspection.org/organization/standards.html
N.A.C.H.I. Standards of
Practice
http://www.nachi.org/sop.htm
W.H.I.L.A.G. Standards of
Practice
http://www.inspectorsjournal.com/forum/uploads/hausdok/WHILAGsopDraft.doc
SOP
COMPARISON
STRUCTURAL
ASHI - 3.
STRUCTURAL SYSTEM
NAHI
- 10. FOUNDATIONS
AII
- 5 SYSTEM: STRUCTURAL COMPONENTS
NACHI – 2.3. BASEMENT, FOUNDATION & CRAWLSPACE
WHILAG - STRUCTURE
Includes structural
components including foundation and framing
Includes the foundation
walls; first-floor systems; other support and sub-structure components; stairs,
ventilation (when applicable); grade slab and/or floor slab.
Includes the visible
structural components including foundations and other support and anchoring
components; floors and visible floor framing; substructure and substructure
ventilation; walls; ceilings; stairs; roofs and visible roof framing; and the
presence of drainage systems; sump pumps and related equipment.
Includes the basement;
foundation; crawlspace; visible structural components.
Includes
the foundation walls; first-floor systems; roof framing and decking; other
support and sub-structure components; stairs, ventilation (when applicable);
grade slab and/or floor slab.
The
inspector shall:
The
Inspector will:
The
inspector shall:
The
inspector shall:
The Inspector
will:
Inspect
the structural components including foundation and framing by probing a
representative number of structural components where deterioration is suspected
or where clear indications of possible deterioration exist. Probing is not
required when proving would damage any finished surface or where no
deterioration is visible.
Inspect foundations for
indications of flooding, moisture, or water penetration
Inspect the basement;
the foundation; the crawlspace; the visible structural components; any present
conditions or indications of active water penetration by probing a
representative sampling of structural components where deterioration is believed
to be present or where clear indications of deterioration are present.
Inspect
foundations for indications of flooding, moisture, or water penetration and/or
any visible and accessible wooden members.
Describe the
foundation and report the methods used to inspect the under-floor crawl space;
the floor structure; the wall structure; the ceiling structure; the roof
structure and report the methods used to inspect the attic.
Describe the type of
structure and material comprising the structure and other items inspected;
Describe
the type of structure and material comprising the structure and other items
inspected as well as the material comprising the roof structure in the visible
attic areas.
Observe the condition
and serviceability of visible, exposed areas of foundation walls, grade slab,
bearing walls, posts, piers, beams, joists, trusses, sub-floors, chimney
foundations, stairs, and other similar structural components; the visible
condition of floor slab when present and observe sub-floor crawl space
ventilation and vapor barriers
Observe and report
on visible structural components including foundations and other support and
anchoring components; floors and visible floor framing; substructure and
substructure ventilation; walls; ceilings; stairs; roofs and visible roof
framing; and the presence of drainage systems, sumps, sump pumps and related
equipment.
Observe
the condition and serviceability of visible, exposed areas of foundation walls,
grade slab, bearing walls, posts, piers, beams, joists, trusses, sub-floors,
chimney foundations, stairs, and other similar structural components, including
the condition of the visible roof structure and attic components where readily
and safely accessible; the visible condition of floor slab when present and
observe sub-floor crawl space ventilation and vapor barriers.
Operate
the sump pump when present; inspect the visible and accessible wooden members
Identify the type of
foundation, floor structure, wall structure, roof structure, ceiling structure.
Evaluate components
where deterioration is suspected. Probing is NOT required when probing would
damage any finished surface.
Enter under floor
crawl spaces and attic spaces.
Report the methods
used to observe under floor crawl spaces and attics when these areas are not
entered or when access or visibility is limited and any signs of unusual or
harmful water penetration into/onto the structure or structural components.
Report
any general indications of foundation movement that are observed, such as but
not limited to sheetrock cracks, brick cracks, out-of-square door frames or
floor slopes.
Probe
a representative number of structural components where deterioration is
suspected or where clear indications of possible deterioration exist. Probing is
not required when probing will damage any finished surface or where no
deterioration is visible.
The
inspector is not required to:
The
inspector is not required to:
The
inspector shall not (be) required to:
The
inspector is not required to:
The inspector
is not required to:
Provide any
engineering service or architectural service.
Provide
any engineering or architectural service.
Offer an opinion as to
the adequacy of any structural system or component.
Enter
sub-floor crawl spaces with headroom of less than 3 feet, obstructions, or other
detrimental conditions or areas, which in the inspector’s opinion, may contain
conditions or materials hazardous to the health and safety of the Inspector.
Enter
substructure areas that are not accessible or where entry could cause damage or
expose the inspector to a hazard; crawlspaces or attic spaces where access
opening is less than 18” x 24”; under floor crawl spaces when obstructed,
restricted or when headroom is less than 18 inches below the floor joists;
attics when there is less than 36 inches below rafters or when entry could
damage the property, or when dangerous or adverse situations are suspected.
Enter
any crawlspaces that are not readily accessible or where entry could cause
damage or pose a hazard to the inspector in his or her opinion.
Enter
any sub-floor crawlspaces with an access opening less than 18 inches by 24
inches or headroom less than 18 inches beneath floor joists and 12 inches
beneath girders or those areas with other obstructions or detrimental
conditions, which, in the inspector’s opinion, contain conditions or materials
hazardous to the health and safety of the inspector.
Move
stored items or debris or perform excavation to gain access.
Move
owner stored items or furnishings, vegetation or debris, or perform any
excavations or other intrusive functions to gain access to systems or
components.
Move
stored items or debris.
Move
stored items or debris or perform excavation to gain access.
Operate sump pumps
equipped with internal/water dependent switches.
Operate
or evaluate the adequacy of sump pumps or drainage systems.
Operate
sump pumps with inaccessible floats.
Identify size or
adequacy of any bolting or bracing systems in the substructure.
Identify
size, spacing, span, location or adequacy of foundation bolting, bracing, joists
or support systems.
Perform
any intrusive examination or testing.
Report on the adequacy
of any structural system or component.
EXTERIOR
ASHI
- 4. EXTERIOR
NAHI
- 5. EXTERIOR
AII
- 6 - SYSTEM: EXTERIOR
NACHI – 2.2. EXTERIOR
WHILAG -
EXTERIOR
Includes the exterior
wall covering flashing and trim; all exterior doors; attached decks, balconies;
stoops; steps; porches and their associated railings; eaves; soffits and fascia
where accessible from ground level; vegetation, grading, surface drainage;
retaining walls on the property when any are likely to adversely affect the
building; walkways, patios, and driveways leading to dwelling entrances.
Includes
visible structural components; wall covering, trim, and protective coating;
windows and doors: attached porches, decks, steps, balconies, handrails,
guardrails, and carports: visible exterior portions of chimneys
Includes
exterior wall coverings, flashings and trim; primary windows and doors; garage
door operators; attached garages and carports; attached decks, balconies,
stoops, steps, columns, areaways, and porches including handrailings and
guardrails; eaves, soffits and fascias; and vegetation, grading, drainage,
driveways, patios, walkways and retaining walls with respect to their effect on
the condition of the building.
Includes
the flashing and trim; all exterior doors, decks, stoops, steps, stairs,
porches, railings, eaves, soffits, fascias, grading and walkways.
Includes
the visible structural components; wall covering, trim, protective coatings and
sealants; windows and doors; attached porches, decks, steps, balconies,
handrails, guardrails, and carports; eaves, soffits and fascias; and visible
exterior portions of chimneys.
The inspector
shall:
The
Inspector will:
The
inspector shall:
The
inspector shall:
The Inspector
will:
Inspect
the exterior wall covering, flashing and trim; all exterior doors; attached
decks, balconies, stoops, steps, porches, and their associated railings; the
eaves, soffits, and fascias where accessible from the ground level; the
vegetation, grading, surface drainage, and retaining walls on the property when
any of these are likely to adversely affect the building; and walkways, patios,
and driveways leading to dwelling entrances
Inspect
attached porches, decks, steps, balconies, handrails, and guardrails.
Inspect
the flashing and trim; all exterior doors, decks, stoops, steps, stairs,
porches, railings, eaves, soffits, fascias, grading, and walkways.
Inspect
attached porches, decks, steps, balconies, handrails, and guardrails by probing.
Observe and report
on exterior walls coverings and trim; primary windows and doors; garage door
operators; attached garages and carports; attached decks, balconies, stoops,
steps, columns, areaways; porches including hand railings and guardrails; eaves
soffits and fascias; and vegetation, grading, drainage, driveways, patios,
walkways and retaining walls with respect to their effect on the condition of
the building. (Retaining walls are reported on based on their existence, visual
function and whether weep holes are present. The adequacy and engineering
aspects are left to the appropriate professional).
Observe
the condition of the components from the ground level and the condition of a
representative number of visible windows and doors.
Observe
the condition of the components from the ground level and the condition of a
representative number of visible windows and doors.
Describe
the exterior wall covering and the type and material comprising the exterior
components inspected.
Describe
the exterior wall covering.
Describe
the type and material comprising the exterior components inspected.
Identify exterior wall
covering materials.
Operate all exterior
doors, including garage doors, manually or by using permanently installed
controls of any garage door operator.
Report whether or not
any garage door operator will automatically reverse when meeting reasonable
resistance during closing and/or when the electronic eye beam (if installed) is
interrupted.
Report
as in need of repair any spacings between intermediate balusters, spindles, or
rails for steps, stairways, balconies, and railings that permit the passage of
an object greater than four inches in diameter; the vegetation, surface drainage
and retaining walls when these are likely to adversely affect the building.
The
inspector is not required to:
The
Inspector is not required to:
The
inspector is not required to:
The
inspector is not required to:
The Inspector
is not required to:
Inspect screening,
shutters, awnings, and similar seasonal accessories; fences; geological,
geo-technical or hydrological conditions; recreational facilities; outbuildings;
seawalls, break-walls, and docks; and erosion control and earth stabilization
measures.
Inspect
buildings, decks, patios, retaining walls, and other structures detached from
the house; inspect or test the operation of security locks, devices or systems;
or inspect for safety type glass or the integrity of thermal window seals or
damaged glass.
Inspect
or operate screens, storm windows, shutters, awnings, fences,
outbuildings, or exterior accent lighting; items, including window and door
flashings, which are not visible or readily accessible from the ground;
geological, geo-technical, or hydrological conditions; recreational facilities;
seawalls, break-walls and docks; erosion control and earth stabilization
measures; for safety type glass; underground utilities; underground items; wells
or springs; solar systems; swimming pools or spas; septic systems or cesspools;
playground equipment; sprinkler systems and drain fields or drywells.
Inspect
buildings, decks, patios, retaining walls, and other structures detached from
the house; inspect or test the operation of security locks, devices or systems;
inspect for safety type glass or the integrity of thermal window seals or
damaged glass; or enter areas beneath decks with less than 5 feet of clearance
from the underside of joists to grade.
Evaluate the function
of shutters, awnings, storm doors, storm windows and similar accessories or the
presence, extent, and type of insulation and vapor barriers in the exterior
walls.
Evaluate
the function of shutters, awnings, storm doors, storm windows and similar
accessories or the presence, extent, and type of insulation and vapor barriers
in the exterior walls.
Examine
the interior of the chimney flues or determine the presence or absence of flu
liners.
Examine
the interior of the chimney flues or determine the presence or absence of flu
liners.
Report
on garage door operator remote control transmitters; operation or condition of
storm doors, storm windows, screening, shutters or awnings; geological,
geotechnical or hydrological conditions; soil conditions; recreational
facilities, including, but not limited to, spas, saunas, steam baths, swimming
pools, tennis courts, playground equipment, and other exercise, entertainment,
or athletic facilities (unless specifically contracted for by the client and the
inspector possesses the proper technical expertise, training and applicable
State licensing and/or certification for such inspections); foundation, roof and
all underground drainage systems; detached outbuildings and structures, other
than primary parking garage and carport, unless specifically contracted for
inclusion in the report by the client; areas or items that are not visible from
a readily accessible walking surface; waterfront boathouses, piers and docks,
waterfront bulkheading and outdoor barbecues.
Determine the
integrity of the thermal window seals or damaged glass.
ROOFS
ASHI
- 5. ROOF SYSTEM
NAHI
- 6.ROOF COVERINGS, FLASHINGS, GUTTERS, DOWNSPOUTS AND ROOF VENTILATION
AII - 7 - SYSTEM: ROOFING
NACHI - 2.1. ROOF
WHILAG -
ROOFS
Includes the roof
covering; the roof drainage systems; the flashings; the skylights, chimneys, and
roof penetrations.
Includes
the roof covering material; rain gutter and downspout system; visible portions
of roof flashings; roof ventilation; roof soffits and fascias; roof skylights
and other roof accessories.
Includes
the roof coverings; roof drainage systems; flashings; skylights, chimneys and
roof penetrations; visible condition of the exterior of the chimney and flues,
guying systems for antennae or TV dish systems.
Includes
the roof covering; gutters; downspouts; vents, flashings, skylights, chimneys
and other roof penetrations.
Includes
the roof covering material; rain gutter and downspout system; visible portions
of roof flashings; roof ventilation; skylights, and roof penetrations; and the
portions of the chimney and flues visible from the exterior.
The
inspector shall:
The
Inspector will:
The
inspector shall:
The
inspector shall:
The Inspector
will:
Inspect
the roof covering; roof drainage systems; flashings; skylights/ chimneys and
roof penetrations.
Inspect
(if possible) the roof surface and components from arms-length distance or with
binoculars from the ground; flat roofs where internal accessibility is readily
and safely available.
Inspect
from ground level or the eaves the roof covering; gutters; downspouts; vents,
flashings, skylights and other roof penetrations; the general structure of the
roof from the readily accessible panels, doors or stairs.
Inspect
the roof covering; roof drainage systems; flashings; skylights; chimneys and
roof penetrations.
Observe the condition
of visible roof material, rain gutter and downspout systems, visible portions of
roof flashings, roof soffits and fascias, roof vents, skylights and other roof
accessories visible from the exterior.
Observe
the roof and report on roof coverings; roof drainage systems; flashings;
skylights, chimneys and roof penetrations; visible condition of the exterior of
chimneys and flues; the appearance of instability or missing attachment or
guying system for antennae or TV dish system; and signs of leaks or abnormal
water intrusion into/onto building components.
Observe
the condition of visible roof material, rain gutter and downspout systems,
visible portions of roof flashings, roof soffits and fascias, roof vents,
skylights and roof drainage systems.
Identify
the type of roof covering materials.
Describe
the roof covering and report the methods used to inspect the roof.
Describe
the type of roofing and gutters.
Describe
the type of roofing and gutters.
Report the methods
used to observe the roofing; the overall condition of the roofing; and any
conditions that are damaging to the roof.
Report
the presence of roof ventilation.
Report
the methods used to inspect the roof and the presence or absence of roof
ventilation.
The inspector is not required to:
The
Inspector is not required to:
The
inspector is not required to:
The
inspector is not required to:
The Inspector
is not required to:
Inspect antennae;
interiors of flues or chimneys that are not readily accessible and other
installed accessories.
Inspect
internal gutter and downspout systems and related underground drainage piping
and antennas, lightning arresters, or similar attachments.
Inspect
underground downspout diverter drainage pipes; antennae; lightning arresters or
similar attachments.
Inspect
internal gutter and downspout systems and related underground drainage piping
and antennas, lightning arresters, or similar attachments.
Walk
on or access a
roof where it could damage the roof or roofing material or be unsafe for the
Inspector.
Walk
on the roofing when walking could damage the property or be unsafe to the
inspector.
Walk
on any roof surface.
Walk on
or access a roof where it could damage the roof or roofing material or be
unsafe for the Inspector.
Remove snow, ice,
debris or other conditions that prohibit the observation of the roof surfaces
Remove
snow, ice, debris or other conditions that prohibit the observation of the roof
surfaces.
Remove
snow, ice, debris or other conditions that prohibit the observation of the roof
surfaces
Operate
powered roof ventilators.
Operate
powered roof ventilators.
Determine
remaining life expectancy of roof coverings, presence or absence of hail damage;
manufacturers’ defects, exceptions, installation methods or recalls; number of
layers or adequacy of roof ventilation.
Determine
remaining life expectancy of roof coverings, presence or absence of hail damage;
manufacturers’ defects, exceptions, installation methods or recalls; number of
layers or adequacy of roof ventilation.
Report
on any antennae or Satellite dish system function, operation or its grounding
system or on the interior of flues or chimneys that are not readily accessible
and/or visible.
Predict the service
life expectancy.
PLUMBING
ASHI - 6.
PLUMBING SYSTEM
NAHI – 10. PLUMBING
AII - 8 - SYSTEM:
PLUMBING
NACHI - 2.6. PLUMBING
WHILAG -
PLUMBING
SYSTEM
Includes
the interior water supply and distribution systems including fixtures and
faucets; the drain waste and vent systems including fixtures; the water heating
equipment; the vent systems, flues and chimneys; the fuel storage and fuel
distribution systems; and the drainage sumps, sump pumps, and related piping.
Includes
visible water supply lines; visible waste/soil and vent lines; fixtures and
faucets; domestic hot water system and fuel source.
Includes
the interior water supply and distribution system including piping materials,
supports and insulation; fixtures and faucets; visible backflow prevention
devices; interior drain, waste and vent system including traps, drains, waste,
and vent piping and piping supports; cleanouts and any drain line plugs; hot
water systems including water heating equipment, energy source and type of
connection, normal operating controls, safety temperature-pressure relief valve
and drain piping and seismic bracing.
Includes
the main water shutoff valve; the water heating equipment including combustion
air, venting, connections, energy sources, seismic bracing, temperature and
pressure relief valves and/or Watts 210 valves; toilets, sinks, tubs and
showers, interior water supply including all fixtures and faucets; drain waste
and vent systems including fixtures; visible fuel storage systems; and drainage
sump pumps.
Includes
visible water supply lines; visible waste/soil and vent lines; fixtures and
faucets; domestic hot water system and fuel source.
The inspector
shall:
The inspector will:
The inspector
shall:
The inspector
shall:
The inspector
will:
Inspect
the interior water supply and distribution systems including all fixtures and
faucets; the drain waste and vent systems including fixtures; the water heating
equipment; the vent systems, flues and chimneys; the fuel storage and fuel
distribution systems; and the drainage sumps, sump pumps, and related piping.
Inspect
the condition of accessible and visible water and waste lines and inspect
and operate fixtures and faucets, the domestic hot water system and drain pumps
and waste ejector pumps when possible.
Inspect
the main water shut off valve; the water heating equipment, including combustion
air, venting, connections, energy sources, seismic bracing; the interior water
supply including all fixtures and faucets; the drain, waste and vent systems,
including all fixtures; the drainage sump pumps testing sumps with accessible
floats; the water supply, drain, waste and main fuel shut-off valves; the water
supply by viewing the functional flow; mechanical drain-stops at sinks,
lavatories and tubs.
Inspect
the condition of accessible and visible water and waste lines and inspect and
operate all fixtures and faucets and the domestic hot water system when
possible.
Observe
and report on interior water supply and distribution system including
piping materials, supports and insulation; fixtures and faucets; manual flow;
evidence of leaks; presence of cross connections; presence of visible backflow
prevention devices; interior drain, waste and vent system including traps,
drains waste, and vent piping, and piping supports, evidence of leaks, normal
drainage, evidence of lack of drainage or leaking waste drain system, presence
of cleanouts and absence of any drain line plugs; hot water systems including
water heating equipment, energy source and type of connection, normal operating
controls presence of safety temperature-pressure relief valve and drain piping,
combustion air and venting, clearance to combustibles, presence of seismic
bracing; fuel storage and distribution of systems including fuel storage
equipment, supply piping, venting, and supports and evidence of leaks.
Describe
the water supply, drain, waste, and vent piping materials; the water heating
equipment including the energy source; the location of main water and main fuel
shutoff valves.
Describe
the material of the main line and water supply lines; the type of sanitary waste
piping; the type and capacity of domestic water heating unit(s).
Describe
any visible fuel storage systems; water supply, drain, waste and main fuel
shut-off valves, as well as the location of the water main and main fuel
shut-off valves.
Describe
water supply and distribution piping materials; drain, waste and vent materials;
water-heating equipment and report the presence of sump pumps if visible
(evaluation of function or adequacy is not included).
Verify
the presence of a main water supply valve.
Verify
the presence or absence of temperature-pressure relief valves and/or Watts 210
valves.
Verify
the presence of a main water supply valve.
Test
the water supply for functional flow and the waste lines from sinks, tubs and
showers for functional drainage.
Test
the water supply for functional flow and the waste lines from sinks, tubs and
showers for functional drainage.
Operate
all plumbing fixtures, hose bibs, and faucets, where the faucets are not
connected to a household appliance. (Sprinkler systems are not operated).
Identify
water supply and distribution piping materials; drain, waste and vent materials;
water-heating equipment and the presence of sump pump and sewage ejection pumps
if visible (evaluation of function or adequacy is not included).
Flush toilets.
Run
water in sinks, tubs, and showers.
Determine
if the water supply is public or private.
Report
as in need of repair deficiencies in the water supply by viewing the functional
flow in two fixtures operated simultaneously; deficiencies in installation and
identification of hot and cold faucets; mechanical drain-stops that are missing
or do not operate if installed in sinks, lavatories and tubs; commodes that have
cracks in the ceramic material, are improperly mounted on the floor, leak, or
have tank components which do not operate.
The inspector is
not required to:
The Inspector is
not required to:
The inspector is
not required to:
The inspector is
not required to:
The Inspector
is not required to:
Inspect
the clothes washing machine connections; the interiors of flues or chimneys
which are not readily accessible; wells, well pumps, or water storage related
equipment; water conditioning systems; solar water heating systems; fire and
lawn sprinkler systems; private waste disposal systems.
Inspect
any system that is shut-down or secured; any plumbing components not readily
accessible; any exterior plumbing components or interior or exterior drain
systems; interior fire sprinkler systems; water conditioning equipment,
including softener and filter systems; private water supply systems; gas supply
systems for materials, installation or leakage.
Inspect
drainage to or from any appliance, unit, or apparatus to or from said property.
Inspect
interiors of flues or chimneys, water softening or filtering systems, well pumps
or tanks, safety or shut-of valves, floor drains or sprinkler systems; clothes
washing machine connections; water treatment systems or water filters; or
pressure pumps or bladder tanks.
Inspect
any system that is shut-down, secured or winterized; any plumbing components not
readily accessible; any exterior plumbing components or interior or exterior
drain systems; interior fire sprinkler systems; water conditioning equipment,
including softener and filter systems; private water supply systems; gas supply
systems for materials, installation or leakage.
Operate
any main, branch or fixture valve, except faucets or freestanding or built-in
appliances or fixtures and faucets if the flow end of the faucet is connected to
an appliance.
Operate
automatic safety controls; any valve except toilet flush valves, hose bibs and
fixture faucets; any system fixture or component that is shut down, turned off
or disconnected.
Operate
any main, branch or fixture valve except fixture faucets and hose faucets
attached to the building.
Operate
any main, branch or fixture valve, except faucets or freestanding or built-in
appliances or fixtures and faucets if the flow end of the faucet is connected to
an appliance.
Evaluate
the potability of any water supply or the condition and operation of water wells
and related pressure tanks and pumps; the quality or quantity of water from
on-site water supplies; or the condition and operation of on-site sewage
disposal systems such as cesspools, septic tanks, drain fields, related
underground piping, conduit, cisterns, and equipment.
Evaluate
the potability (quality) of water or conformance to any State standards or
design; the gas or propane system for any leakage; gas, liquid propane, or oil
storage tanks.
Evaluate
the potability of any water supply or the condition and operation of water wells
and related pressure tanks and pumps; the quality or quantity of water from
on-site water supplies; or the condition and operation of on-site sewage
disposal systems such as cesspools, septic tanks, drain fields, related
underground piping, conduit, cisterns, and all related equipment.
Test
shower pans, tub and shower surrounds, or enclosures for leakage.
Test
shower pans for leakage or fill any fixture with water during an
inspection.
Test
shower pans, tub and shower surrounds or enclosures for leakage; Watts 210
valves and/or TPR valves.
Test
shower pans, tub and shower surrounds or enclosures for leaking; or the
operation of Watts 210 valves and/or TPR valves.
Determine
water temperature.
Determine
whether water supply and waste disposal systems are public or private or whether
there are sufficient clean-outs installed in the waste system piping.
Determine
the size, temperature, age, life expectancy or adequacy of the water heater; the
exact flow rate, volume, pressure, temperature, or adequacy of the water supply;
the water quality or potability or the reliability of the water supply or
source; the effectiveness of anti-siphon, back-flow prevention or drain-stop
devices; whether there are sufficient clean-outs for effective cleaning of
drains; the adequacy of combustion air.
Determine
water temperature.
Record
location of any on-site visible fuel tanks within or directly adjacent to a
structure.
Record
location of any on-site visible fuel tanks within or directly adjacent to a
structure.
State
the effectiveness (quantitatively or qualitatively) of anti-siphon, back-flow
prevention or drain-stop devices.
Examine
or evaluate the operation of private water systems, including, but not
limited to wells, pumps, tanks, and related equipment or any overflow device of
any fixture.
Examine
ancillary systems or components, such as, but not limited to, those relating to
solar water heating and hot water circulation.
Examine
ancillary systems or components such as, but not limited to, those related to
solar water heating and hot water circulation.
Verify
the functional flow, pressure, temperature or volume at any fixture that is
capped or connected to an appliance.
Report
on water conditioning systems; fire and lawn sprinkler systems; on-site potable
water supply quality and quantity; on-site waste disposal systems; foundation
irrigation systems; jetted tubs, except as to functional flow and functional
drainage; swimming pools, ponds and spas.
(NOTE:
Examination of specific areas may be justified if the Inspector possesses proper
experience, certification and licensing for such examinations and they are
contracted separately, with separate fee structures, between the Inspector and
the Client)
Light
pilot flames.
Light
pilot flames.
Open
closed plumbing access panels.
Excavate
or otherwise uncover the private sewage system or its components to determine
size, adequacy or efficiency.
Evaluate
the compliance with local or state conservation or energy standards, or the
proper design or sizing of any water, waste or venting components, fixtures or
piping; gas, liquid propane or oil storage tanks; time to obtain hot water at
fixtures, or perform testing of any kind to water heater elements.
ELECTRICAL
SYSTEM
A.S.H.I. - 7.
ELECTRICAL SYSTEM
N.A.H.I. - 9.
ELECTRICAL
A.I.I. - 9 - SYSTEM:
ELECTRICAL
N.A.C.H.I. - 2.7.
ELECTRICAL
WHILAG –
ELECTRICAL SYSTEM
Includes
the service drop; the service entrance conductors, cables, and raceways; the
service equipment and main disconnects; the service grounding; the interior
components of service panels and sub panels; the conductors; the overcurrent
protection devices; a representative number of installed lighting fixtures,
switches, and receptacles; the ground fault circuit interrupters.
Includes
the entrance of the primary service from masthead to main panel; main and
sub-panels including feeders; branch circuits, connected devices, and lighting
fixtures; procedures for Inspection.
Includes
the service entrance conductors; service equipment; grounding equipment; main
over-current device; main and downstream distribution panels (subpanels)
(downstream panels are to be in inspected areas.); banch circuit conductors and
their over-current devices; a representative number of installed ceiling fans,
lighting fixtures, switches and receptacles located inside the house and
attached garage, and on the dwelling exterior walls; all accessible outlets; GFI
outlets.
Includes
the service line; the meter box; the main disconnect; panels, breakers and
fuses; the grounding; the bonding; a representative sampling of switches,
receptacles, light fixtures; all GFCI receptacles and GFCI circuit breakers
observed and deemed to be GFCI’s during the inspection; branch circuit wiring if
readily visible; the service entrance conductors and their sheathing; smoke
detectors; drip loops, weatherheads and clearances.
Includes
the entrance of the primary service from masthead to main panel; main and
sub-panels including feeders; branch circuits, connected devices, and lighting
fixtures; procedures for Inspection.
The inspector
shall:
The Inspector
will:
The inspector
shall:
The inspector
shall:
The Inspector
will:
Inspect
the service drop; the service entrance conductors, cables, and raceways; the
service equipment and main disconnects; the service grounding; the interior
components of service panels and sub panels; the conductors; the overcurrent
protection devices; a representative number of installed lighting fixtures,
switches, and receptacles; the ground fault circuit interrupters
Inspect
the main and branch circuit conductors for proper over current protection and
condition by visual observation after removal of the readily accessible main and
sub electric panel cover(s).
Inspect
the service line, drip loops and weatherheads; the meter box; the main
disconnect; panels, breakers and fuses; the grounding; the bonding; a
representative sampling of switches, receptacles, light fixtures; readily
accessible branch circuit wiring; GFCI receptacles and circuit breakers; service
entrance conductors and their sheathing; smoke detectors.
Inspect
the main and branch circuit conductors for proper over current protection and
condition by visual observation after removal of the readily accessible main and
sub electric panel cover(s).
Describe
the amperage and voltage rating of the service; the location of main
disconnect(s) and sub panels; and the wiring methods.
Describe
the type and location of primary service (overhead or underground), voltage,
amperage, and over-current protection devices (fuses or breakers).
Identify
and describe service amperage and voltage; service entry conductor
material; service type as being overhead or underground; location of electrical
main disconnect; location and description of electrical downstream panels (if
located in an inspected area); the presence of any 110-volt solid aluminum
branch circuit wiring.
Describe
the amperage rating of the service.
Describe
the type and location of primary service (overhead or underground), voltage,
amperage, and over-current protection devices (fuses or breakers).
Report
on the presence of solid conductor aluminum branch circuit wiring; on the
absence of smoke detectors.
Report
the presence of aluminum branch circuit wiring at the main and sub-panels.
Report the
presence of
solid conductor aluminum branch circuit wiring if readily visible; any GFCI-tested
receptacles in which power is not present, polarity is incorrect, the receptacle
is not grounded, is not secured to the wall, the cover is not in place, the
ground fault circuit interrupter devices are not properly installed or do not
operate properly, or evidence of arcing or excessive heat is present; the
absence of smoke detectors.
Report as in
need of repair
deficiencies in the integrity of the insulation, drip loop, or separation of
conductors at weatherheads and clearances.
Report
the presence of solid conductor aluminum branch circuit wiring at the main and
sub-panels.
Observe
the existence of a connected grounding conductor when readily accessible and the
general condition of visible branch circuit conductors that may constitute a
hazard to the occupant or the structure by reason of improper use or
installation of electrical components.
Observe
and report on the service entrance conductor type and condition; service
equipment; grounding equipment; main over-current device; main and downstream
distribution panels (sub-panels) (downstream panels are to be in inspected
areas); amperage and voltage ratings of the service; branch circuit conductors,
their over-current devices, and the compatibility of their ampacity and
voltages; the operation of a representative number of installed ceiling fans,
lighting fixtures, switches and receptacles located inside the house and
attached garage, and on the dwelling exterior walls; the polarity and grounding
of all accessible outlets; the presence of GFI outlets within six feet of
interior plumbing fixtures, in the garage or carport, unfinished concrete floor
basements and attached to the exterior of the inspected structure; the operation
of Ground Fault Circuit Interrupters (GFCI) test button; the operation of Arc
Fault Circuit Interrupter (AFCI) breaker test button.
Observe
the existence of a connected grounding conductor when readily accessible and the
general condition of visible branch circuit conductors that may constitute a
hazard to the occupant or the structure by reason of improper use or
installation of electrical components.
Verify
the operation of a representative number of accessible switches, receptacles and
light fixtures; grounding and polarity of a representative number of receptacles
in proximity to plumbing fixtures or on the exterior; and the operation of
ground fault circuit interrupters (GFCI), if present.
Verify
the operation of a representative number of accessible switches, receptacles and
light fixtures; grounding and polarity of a representative number of receptacles
in proximity to plumbing fixtures or on the exterior; and the operation of
ground fault circuit interrupters (GFCI), if present.
Test
all GFCI receptacles and GFCI circuit breakers observed and deemed to be GFCI’s
during the inspection with a GFCI tester.
Test
the operation of installed arc fault circuit interrupters in the service panel.
Determine
the service amperage.
The inspector is
not required to:
The Inspector
is not required to:
The inspector
is not required to:
The inspector
is not required to:
The inspector
is not required to:
Inspect
the remote control devices unless the device is the only control device; the
alarm systems and components; the low voltage wiring, systems and components; or
the ancillary wiring, systems and components not a part of the primary
electrical power distribution system.
Inspect
ancillary systems, including but not limited to: burglar alarms, home protection
systems, low voltage relays, smoke/heat detectors, antennas, electrical de-icing
tapes, lawn sprinkler wiring, swimming pool wiring, or any systems controlled by
timers; or electrical equipment not readily accessible or
Inspect
the alarm system and components; the ancillary wiring; low voltage systems,
electrical de-icing tapes, swimming pool wiring or any time-controlled devices;
private or emergency electrical supply sources, including but not limited to
generators, windmills, photovoltaic solar collectors, or battery or electrical
storage facility; or spark or lightning arrestors.
Inspect
ancillary systems, including but not limited to: timers, burglar alarms, home
protection systems, low voltage relays, smoke/heat detectors, antennas,
electrical de-icing tapes, lawn sprinkler wiring, swimming pool or spa wiring or
electrical equipment not readily accessible.
Measure
amperage, voltage, or impedance.
Measure
amperage, voltage or impedance in any electrical system, device or appliance.
Dismantle
any electrical device or control.
Dismantle
any electrical device or control other than to remove the covers of the main and
auxiliary distribution panels.
Dismantle
any electrical device or control.
Insert
any tool, probe or testing device into the main or sub-panels.
Insert
any tool, probe or testing device inside the electrical panels.
Insert
any tool, probe or device into the main or sub-panels.
Insert
any tool,
probe or testing device into the main or sub-panels.
Activate
electrical systems or branch circuits which are not energized.
Activate
any electrical systems or branch circuits which are not energized.
Activate
electrical systems or branch circuits which are not energized.
Operate
overload protection devices.
Operate
electrical systems or components that are disconnected or switched off at the
main electrical panel.
Operate
electrical systems that are shut down; over current protection devices;
non-accessible smoke detectors; overload devices (?)
Operate
overload protection devices.
Move
any objects, furniture, or appliances to gain access to any electrical
component.
Move
furnishings or storage to gain access to the electrical panel.
Move
any objects, furniture, or appliances to gain access to any electrical
component.
Test
every switch, receptacle, and fixture.
Test
or operate any over-current device except Ground Fault Circuit Interrupters (GFCI)
and Arc Fault Circuit Interrupter (GFCI) breakers using the installed test
buttons.
Test
every switch, receptacle, and fixture.
Remove
switch and outlet cover plates.
Remove
panel covers or dead front covers if not readily accessible.
Remove
switch and outlet cover plates.
Verify
the
continuity of connected service ground(s).
Verify
the continuity of the connected service ground.
Verify
the continuity of connected service ground(s).
Disconnect
any energized system or appliance.
Evaluate
the electrical panel if insufficient clearance does not permit safe access.
Examine
de-icing equipment, private or emergency electrical supply sources, including
but not limited to: generators, windmills, photovoltaic solar collectors, or
battery or electrical storage facilities.
Observe
or report on low voltage systems except to report the presence of
solenoid-type lighting systems; alarm systems, security system devices, heat
detectors or carbon monoxide detectors; intercom telephone, security, TV,
lightning arrestors or other ancillary wiring that is not part of the primary
electrical distribution system; built-in vacuum equipment.
Measure
or determine the amperage or voltage of the main service if not visibly
labeled.
Conduct
drop voltage calculations.
Determine
the accuracy of breaker labeling.
HEATING SYSTEM
A.S.H.I. - 8.
HEATING SYSTEM
N.A.H.I. - 11. CENTRAL
HEATING
A.I.I. - 10 - SYSTEM:
HEATING
N.A.C.H.I. - 2.4.
HEATING
WHILAG -
HEATING
SYSTEM
Includes
the installed heating equipment and the vent systems, flues, and chimneys.
Includes
the fuel source; heating equipment; heating distribution; operating controls;
flue pipes, chimneys and venting; auxiliary heating units.
Includes
the permanently installed heating systems.
Includes
the heating system; the energy source; the heating method
includes
the fuel source; heating equipment; heating distribution; operating controls;
flue pipes, chimneys and venting; auxiliary heating units.
The inspector
shall:
The Inspector
will:
The inspector
shall:
The
inspector shall:
The Inspector
will:
Inspect
the installed heating equipment and the vent systems, flues and chimneys.
Inspect
the operation of fixed supplementary heat units. See 2.6 for more information.
Inspect
the heating system and describe the energy source and heating method using
normal operating controls.
Inspect
the operation of fixed supplementary heat units.
Observe
and report on the permanently installed heating systems including:
heating equipment;
normal operating controls; automatic safety controls; chimneys, flues, and
vents, where readily visible; combustion air supply; clearance to combustibles;
heat distribution systems including blowers, pumps, ducts, piping, radiators,
convectors, registers, air filters, insulation and fan coil units; the presence
of an installed heat source in each room.
Describe
the energy source; and the heating method by its distinguishing characteristics.
Describe
type of fuel, heating equipment, and heating distribution system.
Describe
type of fuel, heating equipment, and heating distribution system.
Operate
the system using normal readily accessible control devices.
Operate
the system(s) using normal operating controls.
Operate
the system using normal readily accessible control devices.
Open
readily accessible access panels or covers provided by the manufacturer or
installer, if readily detachable.
Open
the readily accessible panels provided by the manufacturer or installer for
routine homeowner maintenance.
Open
readily accessible access panels or covers provided by the manufacturer or
installer, if readily detachable.
Observe
the condition of normally operated controls and components of the systems;
visible flue pipes, dampers and related components for functional operation; the
condition of a representative number of heat sources in each habitable space of
the house.
Observe
the condition of normally operated controls and components of the systems;
visible flue pipes, and related components for functional operation; the
condition of a representative number of heat sources in each habitable space of
the house.
Identify
the energy source and type of connection; heating equipment and distribution
type.
Report
whether the inspector deemed the furnace inaccessible.
Report as in
need of repair
furnaces which do not operate.
Report
the absence of combustion air
The inspector is
not required to:
The Inspector
is not required to:
The inspector
is not required to:
The inspector
is not required to:
The inspector
is not required to:
Inspect
the interiors of flues or chimneys which are not readily accessible; the heat
exchanger; the humidifier or dehumidifier; the electronic air filter; the solar
space heating system.
Inspect
or evaluate a heat exchanger; equipment that is not readily accessible;
the interior of chimneys and flues; heating system accessories, such as
humidifiers, air purifiers, motorized dampers, heat reclaimers, etc.; or solar
heating systems.
Inspect
or evaluate interiors of flues or chimneys, fire chambers, the heat exchanger,
the humidifier or dehumidifier, the electronic air filter, solar heating systems
or fuel tanks; underground fuel tanks (?).
Inspect
or evaluate a heat exchanger; equipment that is not readily accessible;
the interior of chimneys and flues; heating system accessories, such as
humidifiers, air purifiers, motorized dampers, heat reclaimers, etc.; solar
heating systems; or concealed distribution systems for any type of heating
system.
Determine
heat supply adequacy or distribution balance.
Determine
clearance to combustibles or adequacy of combustion air.
Determine
the uniformity, temperature, flow, balance, distribution, size, capacity, BTU,
or supply adequacy of the heating system.
Activate
or operate heating or other systems that do not respond to normal
controls or have been shutdown; or heating, heat pump systems, or other systems
when ambient temperatures or other circumstances are not conducive to safe
operation or may damage the equipment.
Activate
heating, heat pump systems, or other heating systems when ambient temperatures
or other circumstances are not conducive to safe operation or may damage the
equipment.
Activate
or operate heating or other systems that do not respond to normal
controls or have been shutdown; or heating, heat pump systems, or other systems
when ambient temperatures or other circumstances are not conducive to safe
operation or may damage the equipment.
Operate
digital-type thermostats or controls.
Operate
heating systems when weather conditions or other circumstances may cause
equipment damage or if, in the opinion of the inspector, the ability to
Operate
electronic thermostats.operate
it is unsafe or hazardous; Automatic safety controls ;
Remove
covers or panels that are not readily accessible.
Remove
covers or panels that are not readily accessible.
Dismantle
any equipment, controls, or gauges.
Dismantle
any equipment, controls, or gauges.
Evaluate
the type of
material contained in insulation and/or wrapping of pipes, ducts, jackets and
boilers; or capacity, adequacy, or efficiency of a heating or cooling system.
Evaluate
fuel quality
Evaluate
the type of material contained in insulation and/or wrapping of pipes, ducts,
jackets and boilers; or capacity, adequacy, or efficiency of a heating or
cooling system, or digital-type thermostats or controls.
Test
or operate gas logs, built-in gas burning appliances, grills, stoves,
space heaters, or solar heating devices.
Test
or operate solar heating devices.
Ignite
or extinguish solid fuel fires.
Light
pilot flames
Ignite
pilot lights.
Start
a gas, propane or oil furnace if shut down or open
any gas, propane or oil supply valve.
Override
automatic safety controls to activate the equipment.
Examine
or evaluate the condition of heat exchangers
Examine
electric heater elements or heat pump fluid/gas materials; below grade systems
and components; or any solar-energy heating systems or components
Report
on the interior of flues or combustion chambers; humidifiers; electronic air
filters; the uniformity or adequacy of heat supply to the various rooms.
Determine
adequacy of combustion air.
AIR
CONDITIONING SYSTEMS
A.S.H.I. - 9. AIR
CONDITIONING SYSTEMS
N.A.H.I. - 12. CENTRAL
AIR CONDITIONING
A.I.I. - 11 - SYSTEM:
CENTRAL AIR CONDITIONING
N.A.C.H.I. - 2.5.
COOLING
WHILAG - AIR
CONDITIONING SYSTEMS
Includes
the installed central and through-wall cooling equipment.
Includes
the cooling equipment; cooling distribution; operating controls; procedures for
Inspection.
Includes
the central air conditioning including cooling and air handling equipment and
normal operating controls; distribution systems including ducts, registers, air
filters, fans, pumps and piping, with associated supports, insulation, and
fan-coil units if different than heating system; presence of an installed
cooling source in each room.
Includes
the central cooling equipment.
Includes
the cooling equipment; cooling distribution; operating controls; procedures for
Inspection.
The inspector
shall:
The Inspector
will:
The inspector
shall:
The inspector
shall:
The Inspector
will:
Inspect
the installed central and through-wall cooling equipment.
Inspect
the central cooling equipment using normal operating controls.
Describe
the energy source; and the cooling method by its distinguishing characteristics.
Describe
the type of central air conditioning system and energy sources.
Describe
the type of central air conditioning system and energy sources.
Operate
the system using normal control devices.
Operate
the systems using normal operating controls.
Operate
the system using normal control devices.
Open
readily accessible access panels or covers provided by the manufacturer or
installer, if readily accessible.
Open
readily accessible and unsecured access panels provided by the manufacturer or
installer for routine homeowner maintenance.
Open
readily accessible access panels or covers provided by the manufacturer or
installer, if readily accessible.
Observe the condition of controls and
operative components of the complete system, conditions permitting; and the
condition of a representative number of the central air cooling outlets in each
habitable space of the house.
Observe
and report on central air conditioning including cooling and air handling
equipment and normal operating controls; distribution systems including ducts,
registers, air filters, fans, pumps and piping, with associated supports,
insulation, and fan-coil units if different than heating system; the presence of
an installed cooling source in each room.
Observe
the condition of controls and operative components of the complete system,
conditions permitting; and the condition of a representative number of the
central air cooling outlets in each habitable space of the house.
Identify
energy sources and cooling equipment type.
Report
on condensate drains where visible and accessible.
The inspector is
not required to:
The Inspector
is not required to:
The inspector
is not required to:
The inspector
is not required to:
The Inspector
is not required to:
Inspect
the electronic air filters.
Inspect
gas-fired refrigeration systems, evaporative coolers, or wall or window-mounted
air-conditioning units.
Inspect
window units, through-wall units, or electronic air filters.
Inspect
or determine thermostat calibration, heat anticipation or automatic
setbacks or clocks.
Inspect
gas-fired refrigeration systems, evaporative coolers, or wall or window-mounted
air conditioning units.
Determine
the cooling supply adequacy or distribution balance.
Determine
uniformity, temperature, flow, balance, distribution, size, capacity,
BTU, or supply adequacy
of the cooling system.
Operate
cooling or other systems that have been shut-down or any equipment or systems if
exterior temperature is below 60° Fahrenheit or when other circumstances are not
conducive to safe operation or may damage the equipment or digital thermostats
or controls.
Operate
equipment
or systems if exterior temperature is below 60 degrees Fahrenheit or when other
circumstances are not conducive to safe operation or may damage the equipment.
Operate
equipment or systems if exterior temperature is below 60° Fahrenheit or when
other circumstances are not conducive to safe operation or may damage the
equipment.
Check
the
pressure of the system coolant, determine the presence of leakage, or the
electrical current drawn by the unit.
Check
the pressure of the system coolant or determine the presence of leakage.
Check
the electrical current drawn by the unit.
Evaluate
the
capacity, efficiency, or adequacy of the system.
Evaluate
the capacity, efficiency, or adequacy of the system.
Evaluate
digital-type thermostats or controls.
Remove
covers or
panels that are not readily accessible.
Remove
covers or panels that are not readily accessible.
Dismantle any equipment, controls, or
gauges.
Dismantle
any equipment, controls, or gauges.
Examine or report on cooling systems
when weather conditions or other circumstances may cause equipment damage;
non-central air conditioners; gas fired, solar or geothermal cooling system;
food, wine or similar storage cooling systems; or any humidity control systems
or components. (Permanently installed wall air conditioning units may be
reported on using normal operating controls.)
Examine
electrical current, coolant fluids or gasses, or coolant leakage.
Report
on the
uniformity or adequacy of cold air supply to the various rooms.
Activate
or operate cooling or other systems that have been shut-down.
INTERIORS
A.S.H.I. - 10.
INTERIOR
N.A.H.I. - 13.
INTERIOR
A.I.I. - 12 - SYSTEM:
INTERIORS
N.A.C.H.I. - 2.10.
DOORS, WINDOWS & INTERIOR
WHILAG –
INTERIORS
Includes
walls, ceilings and floors; steps, stairways and railings; countertops and
installed cabinets.
Includes
the walls, ceilings, floors, windows, and doors; steps, stairways, balconies,
railings; fireplaces; electrical outlets and fixtures; plumbing fixtures and
components; heating and cooling distribution.
Includes
the walls, ceilings and floor surfaces; steps, stairways, balconies, handrails
and guardrails; cabinets and counters; closets; windows and doors, including
hardware; fire separation at chimneys, walls, ceilings, and doors between a
dwelling unit and an attached garage; automatic garage door openers; window
glass and smoke alarms.
Includes
a representative number of doors and windows; walls, ceilings, steps, stairways,
and railings; overhead garage doors and garage door openers, controls and
hardware.
Includes
the walls,
ceilings, floors, windows, and doors; steps, stairways, balconies and railings.
The inspector
shall:
The inspector
will:
The inspector
shall:
The inspector
shall:
The inspector
will:
Inspect
the walls ceilings and floors; steps, stairways and railings; the countertops a
representative number of installed cabinets, doors, and windows and the garage
doors and garage door operators.
Inspect
the exterior condition of the kitchen cabinets and countertops.
Inspect
the walls, ceilings, steps, stairways, and railings; garage doors and garage
door openers by operating first by remote (if available) and then by the
installed automatic door control.
Verify
the presence of steps, stairways, balconies, handrails and guardrails and
observe their condition.
Verify
the presence of steps, stairways, balconies, handrails and guardrails and
observe their condition.
Observe
the visible condition of the surfaces of walls, ceilings, and floors relative to
structural integrity and evidence of water penetration.; the condition of steps,
stairways, balconies, handrails and quardrails; the condition of fireplaces,
dampers, fire boxes and hearths readily visible; and the condition and operation
of plumbing fixtures and components in each room as described in Section 10.
Observe
and report on wall, ceiling, and floor surfaces; steps, stairways,
balconies, hand railings and guardrails; cabinets and counters; closets; windows
and doors including hardware; fire resistant separation at chimneys, walls,
ceilings, and doors between a dwelling unit and an attached garage; the
operation of the auto-reverse safety features on automatic garage door openers
from the installed operator mechanism; the presence of glass that is not safety
glass and location, where the area for visible markings is accessible and
visible; the presence or absence of smoke alarms including testing their
operation through the installed manufacturer supplied test device, if
accessible.
Observe
the visible condition of cabinets and countertops, caulking and grout and the
surfaces of walls, ceilings, and floors relative to structural integrity and
evidence of water penetration.; the condition of steps, stairways, balconies,
handrails and guardrails.
Describe
the type, material, condition and operation of a representative number of
windows, doors and their hardware.
Describe
the condition and operation of a representative number of windows and doors.
Locate
and observe a representative number of electrical outlets/fixtures and wiring in
each room as described in Section 9.
Comment
on presence or absence of smoke detectors.
Comment
on presence or absence of smoke detectors.
Identify
window types
Operate
all accessible primary windows and interior doors.
Report
on visible signs of abnormal or harmful water leakage.
Report
as in need of repair any installed electronic sensors that are not operable or
not installed at proper heights above the garage door; any door locks or side
ropes that have not been removed or disabled when garage door opener is in use;
and windows that are obviously fogged or display other evidence of broken seals.
Open and close
a representative number of doors and windows.
The inspector is
not required to:
The Inspector
is not required to:
The inspector
is not required to:
The inspector
is not required to:
The Inspector
is not required to:
Inspect
the paint, wallpaper and other finish treatments; the carpeting; the window
treatments; the central vacuum systems; the household appliances or recreational
facilities.
Inspect
paint, wallpaper, window treatments or finish treatments; central vacuum
systems; safety glazing in locations subject to human impact; security
components; household appliances; equipment housed in the garage except as
otherwise noted; elevators; remote controls; appliances; items not permanently
installed.
Ignite
fires in a fireplace or stove to determine the adequacy of draft, perform a
chimney smoke test, or inspect any solid fuel device in use.
Evaluate the installation or adequacy of
inserts, wood burning stoves, or other modifications in a fireplace, stove, or
chimney.
Evaluate
the fastening of countertops, cabinets, sink tops and fixtures, or firewall
compromises(?);self-cleaning ovens; signal lights; security bar release and
opening mechanisms, whether interior or exterior including compliance with
local, state, or federal standards.
Determine clearance to combustibles in
concealed areas; cosmetic condition of ceilings, walls, floor coverings, and
components; or whether the bath and/or kitchen vent fan ducting exhausts air to
the exterior of the house.
Determine
leakage from microwave ovens; the adequacy of spa jet water force or bubble
effect; or the structural integrity or leakage of a pool or spa.
Report
on finishes on the interior walls, ceilings, and floors; carpeting; draperies,
blinds, or other window treatments; household appliances; central vacuum,
security or intercom systems; remote operator devices of garage doors.
Move
furniture, stored items, or any coverings like carpets or rugs in order to
inspect the concealed floor structure; drop ceiling tiles; and household
appliances.
Verify
or certify safe operation of any auto reverse or related safety function
of a garage door.
Operate
equipment housed in the garage except as otherwise noted; any system, appliance
or component that requires the use of special keys, codes, combinations, or
devices; self-cleaning oven cycles or signal lights; any sauna, steam-jenny,
kiln, toaster, ice-maker, coffee-maker, can-opener, bread-warmer, blender,
instant hot water dispenser, or other small, ancillary devices.
Examine
any sauna, steam-jenny, kiln, toaster, ice-maker, coffee-maker, can-opener,
bread-warmer, blender, instant hot water dispenser; any above-ground, movable,
freestanding, or otherwise non-permanently installed pool/spa or self-contained
equipment; or any other small, ancillary devices.
Come into contact
with any pool or spa water in order to
determine the system structure or components.
Determine
clearance to combustibles in concealed areas and cosmetic condition of ceilings,
walls, floor coverings and components.
INSULATION AND
VENTILATION
A.S.H.I. - 11.
INSULATION AND VENTILATION
N.A.H.I. - 7.ROOF
STRUCTURE,ATTIC AND INSULATION
A.I.I. - 13 - SYSTEM:
INSULATION AND VENTILATION
N.A.C.H.I. - 2.9.
ATTIC, VENTILATION & INSULATION
WHILAG –
INSULATION AND VENTILATION
Includes
the insulation and vapor retarders in unfinished spaces; ventilation of attic
and foundation areas; and mechanical ventilation systems.
Includes
the roof framing, sheathing and decking; and attic insulation.
Includes
the insulation in unfinished attic and foundation areas; ventilation of attic
and foundation areas; kitchen, bath and laundry venting systems; attic
ventilation fans when present; and storm doors and thermal windows.
Includes
the insulation in unfinishes spaces; ventilation of attic spaces; and mechanical
ventilation systems.
Includes
the insulation and vapor retarders in unfinished spaces; ventilation of attic
and foundation areas; and mechanical ventilation systems.
The inspector
shall:
The Inspector
will:
The inspector
shall:
The inspector
shall:
The inspector
will:
Inspect
the insulation and vapor retarders in unfinished spaces; the ventilation of
attics and foundation areas; and the mechanical ventilation systems.
Inspect
the insulation in unfinished spaces; the ventilation of attic spaces; and
mechanical ventilation systems.
Inspect
the insulation and vapor retarders in unfinished spaces; the ventilation of
attics and foundation areas; and the mechanical ventilation systems.
Describe
the insulation and vapor retarders in unfinished spaces; and the absence of
insulation in unfinished spaces at conditioned surfaces.
Describe
the type of material comprising the roof structure in the visible attic area.
Observe
the condition of the visible roof structure and attic components where readily
and safely accessible.
Describe
the insulation in unfinished spaces and the absence of insulation in unfinished
spaces at conditioned surfaces.
Observe
and report on insulation in unfinished attic and foundation areas;
ventilation of attic and
foundation areas; kitchen, bath, and laundry venting systems and whether the
vents terminate at the exterior of the dwelling; presence of any attic
ventilation fan; presence or absence (only) of storm doors or thermal windows;
and evidence of visible condensation and other consequences of inadequate
ventilation.
Investigate
evidence of the presence of water penetration.
Determine
the presence of attic insulation and its approximate thickness.
Identify
insulation in unfinished attics and under-floor crawlspaces and estimated
quantity; the absence or presence of insulation in unfinished spaces next to
heated living areas.
Report
on the general absence or lack of insulation.
Report
the absence of insulation on heating ductwork and water supply plumbing in
unconditioned spaces.
The inspector is
not required to:
The inspector
is not required to:
The inspector
is not required to:
The inspector
is not required to:
The inspector
is not required to:
Disturb
insulation or vapor retarders.
Disturb
insulation or vapor retarders.
Determine
indoor air quality.
Determine
indoor air quality.
Determine
the types of materials used in insulation/wrapping of pipes, ducts, jackets,
boilers, and wiring.
Enter
attic spaces with headroom of less than 5 feet, with insulation covering the
ceiling joist, or bottom truss cord, or if there are obstructions, trusses, or
other detrimental
conditions.
Enter
the attic or unfinished spaces that are not readily accessible or where entry
could cause damage or pose a safety hazard to the inspector in his or her
opinion.
Enter
attic spaces that are not readily accessible.
Break or
otherwise damage
the surface finish or weather seal on or around access panels and covers.
Break or
otherwise damage
the surface finish or weather seal on or around access panels and covers.
Break
or otherwise damage the surface finish or weather seal on or around
access panels and covers.
Report
on insulation and vapor retarders concealed in ceilings or exterior walls;
venting equipment and fans that are integral with household appliances; or the
thermal efficiency ratings or concealed ventilation systems.
Move
or touch insulation or vapor retarders.
Identify
the composition or the exact R-value of insulation material.
Activate
thermostatically operated fans.
Operate
powered attic or foundation area ventilation system fans.
FIREPLACES AND
SOLID FUEL BURNING APPLIANCES
A.S.H.I. - 12.
FIREPLACES AND SOLID FUEL BURNING APPLIANCES
N.A.H.I. - 13.1.3
FIREPLACES (Sub-category of Interior)
A.I.I. - 14 - SYSTEM:
FIREPLACES, CHIMNEYS AND SOLID FUEL BURNING APPLIANCES
N.A.C.H.I. - 2.8.
FIREPLACE
WHILAG –
FIREPLACES
AND STOVES
Includes
the system components, vent systems, flue and chimneys.
Includes
fireplaces, dampers, fireboxes and hearths
Includes
Fireplaces and manufactured solid-fuel or gas-burning appliances; the chimneys,
flues, dampers and associated system components; visible areas of the fireboxes;
hearth extensions; mantles; fireplace surrounds and permanently installed
screens and/or glass doors; and seals or gaskets on glass doors.
Includes
the fireplace, damper door if readily accessible and operable; Hearth extensions
and other permanently installed components; lintel, hearth and material
surrounding the fireplace.
Includes
solid fuel and gas fireplaces, stoves, dampers, fireboxes and hearths.
The inspector
shall:
The inspector
will:
The Inspector
shall:
The inspector
shall:
The inspector
will:
Inspect
the system components and the vent systems, flues, and chimneys.
Inspect
and report on the condition of the visible areas of the chimneys, flues,
dampers and associated system components; visible areas of the fireboxes, hearth
extensions, mantles fireplace surrounds and permanently installed screens and/or
glass doors; the installation of manufactured solid-fuel or gas-burning
appliances; and the presence or absence of any seals or gaskets to glass doors.
Inspect
the fireplace; the damper door if readily accessible and operable; hearth
extensions and other permanently installed components; lintel, hearth and
material surrounding the fireplace.
Describe
the fireplaces and solid fuel burning appliances; and the chimneys.
Observe
the condition of fireplaces, dampers, fire boxes and hearths readily visible.
Observe
the condition of fireplaces, stoves, dampers, fire boxes and hearths readily
visible.
Open and close
the damper door if readily accessible and operable.
Report
as in need of repair deficiencies in the lintel, hearth and material surrounding
the fireplace, including clearance from combustible materials
The inspector is
not required to:
The Inspector
is not required to:
The inspector
is not required to:
The inspector
is not required to:
The Inspector
is not required to:
Inspect
the interiors of flues or chimneys; the firescreens and doors; the seals and
gaskets; the automatic fuel feed devices; the mantels and fireplace surrounds;
the combustion make-up air devices; or the heat distribution assists, whether
gravity controlled or fan assisted.
Inspect
the interiors of flues, chimneys or fireplace insert flue connection beyond
visible areas; the automatic fuel feed devices; or the combustion make-up
devices.
Inspect
the vent system; the interior of the chimney or flue, fire doors or screens,
seals or mantels; automatic fuel feed devices; combustion make up devices; or
heat distribution assists whether gravity controlled or fan assisted.
Inspect
the interior of flues or chimneys or any solid fuel device in use
Ignite
or extinguish fires.
Ignite
fires in a fireplace or stove to determine the adequacy of draft, perform a
chimney smoke test, or inspect any solid fuel device in use.
Ignite
or extinguish fires.
Ignite
or extinguish fires.
Light
pilot flames.
Ignite
fires in a fireplace or stove to determine the adequacy of draft, perform
a chimney smoke test, or.
Determine
draft characteristics.
Determine
draft characteristics or the structural integrity of fireplaces or chimneys.
Determine
the need for a chimney sweep; draft characteristics; or adequacy of draft; or
the appropriateness of such installation.
Move
fireplace inserts or stoves or firebox contents.
Move
fireplace inserts or stoves or firebox contents.
Move
fireplace inserts or stoves or firebox contents.
Evaluate
the installation or adequacy of inserts, wood burning stoves, or other
modifications in a fireplace, stove, or chimney.
Evaluate
the installation or adequacy of inserts, wood burning stoves, or other
modifications in a fireplace, stove, or chimney.
Operate
gas fireplace inserts.
Perform
a smoke test.
Dismantle or
remove
any component.
Dismantle
fireplaces or stoves to inspect chimneys or fireboxes.
SITE
A.S.H.I. – No Site
section – Included in the Exterior section
N.A.H.I. - 3. SITE
A.I.I. - 4 - SYSTEM:
SITE CHARACTERISTICS
N.A.C.H.I. - No
Site section – Included in the Exterior section
WHILAG – SITE
NOTE:
There isn’t actually a SITE section in the ASHI SOP or NACHI SOP’s. Site
characteristics are included in the Exteriors section or those SOPs. I’ve used
excerpts of those sections to create a comparison.
Includes
the walkways, patios, and driveways leading to dwelling entrances and the
vegetation, grading, surface drainage, and retaining walls on the property when
any of these are likely to adversely affect the building.
Includes
the building perimeter, land grade, and water drainage directly adjacent to the
foundation; trees and vegetation that adversely affect the structure; walks,
grade steps, driveways, patios, and retaining walls contiguous with the
structure.
Includes
site grade and surface water drainage characteristics at the foundation if
observable; condition of walkways and exterior stairways, stoops, landings,
patios and decks; condition of driveways and other paved or masonry areas;
visibly accessible retaining walls and rockeries and earth to wood proximity.
Includes
the exterior grading, walkways and vegetation; and surface drainage and
retaining walls when these are likely to adversely affect the building.
Includes
the building perimeter, land grade, and water drainage directly adjacent to the
foundation; trees and vegetation that adversely affect the structure; walks,
grade steps, driveways, patios, and retaining walls contiguous with the
structure.
The inspector
shall:
The inspector
will:
The inspector
shall:
The inspector
shall:
The inspector
will:
Inspect
the vegetation, grading, surface drainage, and retaining walls on the property
when any of these are likely to adversely affect the building; and walkways,
patios, and driveways leading to dwelling entrances.
Inspect
fences or privacy walls.
Inspect
all exterior grading, and walkways and the vegetation, surface drainage and
retaining walls when these are likely to adversely affect the building.
Describe
the type of material and inspect the condition of the driveways, walkways, grade
steps, patios, and other items contiguous with the inspected structure.
Describe
the type of material and inspect the condition of the driveways,
walkways, grade steps, patios, and other items contiguous with the inspected
structure.
Observe
the drainage, grading, and vegetation for conditions that adversely affect the
structure.
Observe
and describe site grade and surface water drainage characteristics at the
foundation if observable (Most buildings have shrubbery or other growth around
the property that limit or eliminate the ability of the inspector to visualize
the drainage or grade of the property); the condition of walkways and exterior
stairways, stoops, landings, patios and decks; the condition of driveways and
other paved or masonry areas; visibly accessible retaining walls and rockeries;
and earth to wood proximity.
Observe
the drainage, grading, and vegetation for conditions that adversely affect the
structure.
Report
as in need of repair any vegetation, surface drainage and retaining walls
adversely affecting the building.
The inspector is
not required to:
The Inspector
is not required to:
The Inspector
shall not:
The inspector
is not required to:
The Inspector
is not required to:
Inspect
fences; geological, geo-technical or hydrological conditions; seawalls,
break-walls, and docks; and erosion control and earth stabilization measures.
Inspect
geological, geotechnical, or hydrological conditions; seawalls, break-walls and
docks; erosion control and earth stabilization measures; or drain fields or
drywells.
Inspect
fences or privacy walls.
Evaluate
the condition of trees, shrubs, and or other vegetation; soil or geological
conditions, site engineering or property boundaries.
Evaluate
the condition of trees, shrubs, and or other vegetation; soil or geological
conditions, hydrological conditions; seawalls, break-walls, and docks; site
engineering or property boundaries.
Determine soil or geological conditions,
site engineering, or property boundaries.
Determine
soil or geological conditions, site engineering, or property boundaries.
Report
ownership of property, fencing, privacy walls, retaining walls, or related
issues; the condition of trees, shrubs, or vegetation; soil or geological
conditions, site engineering, property boundaries, encroachments or easements;
the adequacy of retaining walls, sea walls, waterfront bulkhead, docks and
piers; ponds, fountains or decorative water features, unless said
inspections are contained within a separate contract.